Analisis Pengaruh Penambahan Solar Panel Pada Bangunan Warehouse terhadap Kinerja Pre Engineered Building
DOI:
https://doi.org/10.58192/ocean.v5i3.5541Keywords:
Pre-Engineered Building, Solar Panels, Steel Structure, Utilization Ratio, WarehouseAbstract
The integration of renewable energy systems, particularly rooftop solar panels, in industrial buildings has increased as part of efforts to improve energy efficiency and sustainability. However, the installation of solar panels on a Pre-Engineered Building (PEB) introduces additional permanent loads that may affect structural performance. This study aims to evaluate the effect of solar panel installation on the structural performance of a PEB warehouse in Medan. The analysis was conducted by comparing the existing structural condition with the condition after the addition of a solar panel load of 0.15 kN/m². A structural model was developed using structural analysis software, while the evaluation considered the utilization ratio (UR) of selected structural members, including the main column, rafter haunch, roof purlin, rafter mid span, and end wall column. The results indicate that solar panel installation increases the utilization ratio of all evaluated structural members. The roof purlin experienced the highest increase, from 0.74 to 0.91, corresponding to 22.97%, while the rafter haunch showed the lowest increase of 11.54%. The critical structural member also shifted from the main column in the existing condition (UR = 0.79) to the roof purlin after solar panel installation (UR = 0.91). Nevertheless, the maximum utilization ratio remains below 1.00, indicating that the evaluated structural members remain within their design capacity. The findings demonstrate that rooftop solar panel installation can be implemented on PEB structures with appropriate structural assessment and load evaluation.
References
Alrawashdeh, H., & Stathopoulos, T. (2023). Wind loading of rooftop PV panels cover plate: A codification-oriented study. Journal of Wind Engineering and Industrial Aerodynamics, 240, 105489. https://doi.org/10.1016/j.jweia.2023.105489
Badan Standardisasi Nasional. (2019). SNI 1726:2019: Tata cara perencanaan ketahanan gempa untuk struktur bangunan gedung dan nongedung. Badan Standardisasi Nasional.
Badan Standardisasi Nasional. (2020a). SNI 1727:2020: Beban desain minimum dan kriteria terkait untuk bangunan gedung dan struktur lain. Badan Standardisasi Nasional.
Badan Standardisasi Nasional. (2020b). SNI 1729:2020: Spesifikasi untuk bangunan gedung baja struktural (ANSI/AISC 360-16, IDT). Badan Standardisasi Nasional.
Bentley Systems, Inc. (2024). STAAD.Pro: Structural analysis and design software. Bentley Systems.
Choi, H., Shedo, D. A., & Chang, B. (2024). Serviceability analysis and feasibility study of ballasted rooftop PV system on existing concrete roof slab buildings. Renewable Energy, 228, 120622. https://doi.org/10.1016/j.renene.2024.120622
Dai, S. F., Liu, H. J., Yang, J. H., & Peng, H. Y. (2022). Wind loads on roof-mounted isolated solar panels of tall buildings through wind tunnel testing. Solar Energy, 231, 607–622. https://doi.org/10.1016/j.solener.2021.12.005
Dai, S. F., Liu, H. J., Lam, H. F., & Peng, H. Y. (2025). Interference effect of photovoltaic solar arrays on wind load of building roof by large eddy simulations. Engineering Structures, 336, 120453. https://doi.org/10.1016/j.engstruct.2025.120453
Estephan, J., Gan Chowdhury, A., & Irwin, P. (2022). A new experimental-numerical approach to estimate peak wind loads on roof-mounted photovoltaic systems by incorporating inflow turbulence and dynamic effects. Engineering Structures, 252, 113739. https://doi.org/10.1016/j.engstruct.2021.113739
Galevien, A. P., Ridwan, M. K., & Wardana, A. N. I. (2025). Assessing the viability of rooftop solar PV in energy-intensive industries: A techno-economic and safety framework for the Indonesian FMCG sector. Energies, 18(21), 5859. https://doi.org/10.3390/en18215859
Kavitha, R., Logeshwaran, S., Sabarinathan, S., & Vijai Anand, V. (2023). Structural analysis and design for a warehouse using STAAD PRO. Materials Today: Proceedings. https://doi.org/10.1016/j.matpr.2023.04.479
Mendes, S., Ellowitz, J., & Xu, H. (2022). Evaluation of existing buildings for feasibility of photovoltaic array installation. In Forensic Engineering 2022. American Society of Civil Engineers. https://doi.org/10.1061/9780784484548.008
Mostofi, F., Tokdemir, O. B., & Togan, V. (2020). Structural performance of an existing building roof subjected to additional PV panel load. In 2020 2nd International Conference on Photovoltaic Science and Technologies (PVCon) (pp. 1–6). https://doi.org/10.1109/PVCon51547.2020.9757801
Nerlekar, H. H., & Radhika, K. L. (2024). Analytical study of pre-engineered building subjected to lateral loads. Tuijin Jishu/Journal of Propulsion Technology, 45(3). https://doi.org/10.52783/tjjpt.v45.i03.7635
Pardhi, S., Bandewar, D., & Jat, S. (2022). Analysis of warehouse structure in pre-engineered building with conventional steel building. International Journal for Research in Applied Science and Engineering Technology, 10(9), 1093–1102. https://doi.org/10.22214/ijraset.2022.46750
Peng, H. Y., Dai, S. F., & Liu, H. J. (2023). Wind loading characteristics and roof zoning of solar arrays mounted on flat-roofed tall buildings. Journal of Building Engineering, 66, 105823. https://doi.org/10.1016/j.jobe.2023.105823
Rao, J. V., Ramana, K. V., & Rao, B. N. (2024). Analysis and design of pre-engineered industrial warehouse using IS: 800 and AISC. ARPN Journal of Engineering and Applied Sciences, 19(3), 154–159. https://doi.org/10.59018/022427
Sah, S. K., Kangda, M. Z., Sathe, S., & Mate, N. (2023). A state of art review on analysis and design of pre-engineered buildings. Materials Today: Proceedings, 77, 704–710. https://doi.org/10.1016/j.matpr.2022.11.361
Sari, D. Y., & Pratiwi, A. R. (2024). Analisis kelayakan struktur eksisting pada bangunan warehouse untuk pemasangan panel surya. Jurnal TESLINK: Teknik Sipil dan Lingkungan, 6(1), 244–253. https://doi.org/10.52005/teslink.v6i1.405
Tomar, S., & Grover, R. (2024). Analysis and design of pre-engineered industrial warehouse building with different base condition. International Journal for Research in Applied Science and Engineering Technology, 12(12), 1132–1138. https://doi.org/10.22214/ijraset.2024.66009
Yao, J. F., Tu, Z. B., Shen, G. H., Guo, Y., & Wang, D. (2024). Experimental investigation of wind pressures on photovoltaic (PV) panel installed parallel to residential gable roof. Solar Energy, 271, 112452. https://doi.org/10.1016/j.solener.2024.112452
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2026 Ocean Engineering : Jurnal Ilmu Teknik dan Teknologi Maritim

This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.