Evaluasi Tahanan Isolasi dan Indeks Polarisasi pada Generator Set Diesel 350 kVA
DOI:
https://doi.org/10.58192/unitech.v5i1.4897Keywords:
Insulation Resistance, Polarization Index, Diesel Generator, IEEE 43-2024, Preventive Maintenance.Abstract
The reliability of a Generator Set (Genset) as a backup power supply heavily depends on the integrity of its dielectric insulation system, especially when operating in a tropical coastal environment prone to thermal stress and high humidity. This study aims to evaluate the Insulation Resistance (IR) and Polarization Index (PI) of a 350 kVA generator based on the IEEE 43-2024 standard, and to analyze the conductor resistance balance referring to ANSI/EASA AR100-2025. The research method includes verifying the cooling circulation space, conducting a 1,000 V DC voltage injection test for 10 minutes, and measuring the low-order direct current resistance on the stator windings. Evaluation results show that the insulation resistance values on the stator, power cables, and circuit breaker exceed the instrument's limit (>1,000 MΩ), indicating minimal leakage current and excellent insulation condition. The Polarization Index (PI) value was recorded at a ratio of 2.0 (categorized as Good). A maximum resistance asymmetry deviation of 4.35% was found in the T-R phase, which still meets the operational tolerance limit. It is concluded that the generator unit is in a highly feasible operating condition. As a preventive measure in coastal areas, operating the internal space heater while the unit is on standby is recommended to prevent the accumulation of microscopic condensation.
References
Wawoh Devi P., M. C. Glanny, Mangindaan, & Patras Lily S. (2023). Analysis Lifetime of Generator Based On It’s Calculate Insulation. Jurnal Teknik Elektro Dan Komputer, 13, 19–26. https://ejournal.unsrat.ac.id/index.php/elekdankom
Aditya Pasaribu Ivan, Nur Pertiwi Masitoh, Ibnu Habib Faiz, & Jonto Sinaga Desman. (2025). ANALISIS HASIL PENGUJIAN TAHANAN ISOLASI (IR) DAN POLARIZATION INDEX (PI) PADA MOTOR INDUKSI TIGA FASA 6 KV SISTEM CIRCULATING WATER PUMP (CWP) DI PLTGU PT PLN NUSANTARA POWER UNIT PEMBANGKITAN. 6.
BMKG. (2023). Anomali Suhu Udara Rata-Rata Tahun 2023 - Anomali Suhu Udara - BMKG. https://www.bmkg.go.id/iklim/anomali-suhu-udara/anomali-suhu-udara-rata-rata-tahun-2023
EASA_AR100-2025_v1225-01. (n.d.).
IEEE SA - P43. (n.d.). Retrieved May 11, 2026, from https://standards.ieee.org/ieee/43/11466/
Mahendra, L. S., Zulkifli, Z., Herwono, B., Anggraini, Y., Sholikha, E. N., & Nisa, K. (2023). Analisis Kondisi Belitan Stator Generator Melalui Pengujian Indeks Polarisasi dan Tan Delta (Dissipation Factor). Jurnal Teknik Elektro Dan Komputasi (ELKOM), 5(2), 244–251. https://doi.org/10.32528/elkom.v5i2.12716
Muliadi, M., Mado, I., Budiman, A., Subarianto, S., & Rantepadang, A. (2023). Dampak Keandalan Generator Set 3 Fase terhadap Kontinuitas Suplai Listrik saat Terjadi Pemadaman. Emitor: Jurnal Teknik Elektro, 22(2), 144–151. https://doi.org/10.23917/emitor.v22i2.22728
Nishanth, F., Johnson, M., & Severson, E. L. (2021). A Review of Thermal Analysis and Management of Power Dense Electric Machines. 2021 IEEE International Electric Machines and Drives Conference, IEMDC 2021. https://doi.org/10.1109/IEMDC47953.2021.9449520
Rafli Ariwan, M., Pengaruh Perubahan Beban, A., Rafli Ariwan, M., Syahputra, R., Studi Teknologi Rekayasa Pembangkit Energi Jurusan Teknik Elektro, P., & Negeri Lhokseumawe, P. (2023). ANALISIS PERUBAHAN BEBAN TERHDAP KINERJA GENERATOR DI PT. PJB UBJOM PLTMG ARUN. JURNAL TEKTRO, 7(2).
SCHLEICH. (2024). IEEE 43-2024 | Standard for Testing Insulation Resistance of Electric Machinery. https://www.schleich.com/en/test-standard/ieee-43-2024/
Schweiger, J., & Macdonald, R. (2025). Techno-Economic Analysis of Decarbonized Backup Power Systems Using Scenario-Based Stochastic Optimization. Energies, 18(16). https://doi.org/10.3390/en18164388
SNI 0225:2011/AMD 5:2016 Persyaratan Umum Instalasi Listrik 2011 (PUILL 2011) - Amandemen 5 (2011).
Szamel, L., & Oloo, J. (2024). Monitoring of Stator Winding Insulation Degradation through Estimation of Stator Winding Temperature and Leakage Current. Machines, 12(4). https://doi.org/10.3390/machines12040220
Zhang, J., Wang, J., Li, H., Zhang, Q., He, X., Meng, C., Huang, X., Fang, Y., & Wu, J. (2025). A Review of Reliability Assessment and Lifetime Prediction Methods for Electrical Machine Insulation Under Thermal Aging. In Energies (Vol. 18, Number 3). Multidisciplinary Digital Publishing Institute (MDPI). https://doi.org/10.3390/en18030576
Zhu, Z., Bosi, G., Raffo, A., Crupi, G., & Cai, J. (2024). Accurate Modeling of GaN HEMTs Oriented to Analysis of Kink Effects in S22and h21: An Effective Machine Learning Approach. IEEE Journal of the Electron Devices Society, 12, 201–210. https://doi.org/10.1109/JEDS.2024.3364809
Zou, Z., Liu, S., & Kang, J. (2024). Degradation Mechanism and Online Electrical Monitoring Techniques of Stator Winding Insulation in Inverter-Fed Machines: A Review. In World Electric Vehicle Journal (Vol. 15, Number 10). Multidisciplinary Digital Publishing Institute (MDPI). https://doi.org/10.3390/wevj15100444
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2026 Jurnal Universal Technic

This work is licensed under a Creative Commons Attribution 4.0 International License.